Tradewaste/Stormwater Diversion Systems are installed to deal with the fundamental requirements of control authorities and councils to:
Local Control Authorities and the Australian Building Codes Board (ABCB) state that wash-down diversion systems must carry Watermark product certification
Our standard range of diversion systems are listed under separate Watermark Certification drop down tab
Our standard range of pits are Rotomoulded MDPE
Our standard range of pit gratings are Galvanized Mild Steel in Class “B” or “D”
Our standard Diversion Valves and manufactured in Bronze material
Heel proof gratings are available as a special order item for all of our pits
Pits, valves and gratings are available in 316 S.S for special order applications
The Diversion valve system requires a DN 25 Cold Water Supply
Upstream Potable Water Protection being required via an RPZD, as all wash-down areas are classified as a High Hazard – Refer AS 3500.1 = Cold Water Supply – Section 4 and Appendices E&F
Water pressure >150 Kpa is required downstream of the RPZD
They are suitable for Hot Water Applications <80 Deg. C.
Systems with electronic controllers require a 240 Volt 10 Amp Power supply
Design Flow Rates are 20.0 L/Sec @ 0.5 metres head per valve and 20.0 Litres per second through a standard pit with 150mm stormwater outlet
Custom Built Multi Valve systems are available for high discharge flow rate applications
Custom Built Systems are available for any site specific purpose